NMR vs ESR Field Guide
Magnetic resonance · a field guide for doctoral researchers

NMR vs ESROne resonance condition, two particles, three orders of magnitude apart

Nuclear magnetic resonance and electron spin resonance (also called EPR) both drive transitions between Zeeman levels of a spin in a magnetic field. The electron's magnetic moment is about 658 times larger than the proton's. That single number shifts the frequencies, the populations, the relaxation times, the hardware and the questions each method answers. This page works through those consequences with equations and live calculators.

Foundations

The same resonance condition

A magnetic moment in a static field B₀ has 2S+1 or 2I+1 Zeeman levels. Radiation of frequency ν drives magnetic-dipole transitions with Δm = ±1 when hν matches the level splitting. What differs is the size and sign of the moment.

Nuclear spin NMR · I ≥ ½

  • γN is positive for ¹H, ¹³C, ³¹P and negative for ¹⁵N, ²⁹Si.
  • Shielding σ (10⁻⁶ scale) gives the chemical shift δ, the main structural fingerprint.
  • Field is fixed; frequency is swept or, in practice, excited all at once with an RF pulse and Fourier transformed.

Electron spin ESR / EPR · S ≥ ½

  • Free-electron ge = 2.002 319; spin–orbit coupling shifts g, the ESR analogue of the chemical shift.
  • The negative charge flips the sign: the mS = −½ level lies lowest.
  • Microwave frequency is fixed by a resonator; the field is swept in CW work.

Shared machinery

The Bloch equations (1.7) describe both experiments. Equations (1.8) to (1.10) show why the larger γ of the electron dominates: magnetization scales with γ², detected signal with a further power of ω₀ ∝ γB₀. The γ5/2 scaling is a rule of thumb; real sensitivity also depends on linewidth, resonator filling factor and quality factor.

Interactive · equation 1.3 and 1.6

Resonance explorer

Move the field. At any B₀ the electron resonates about 658 times higher than ¹H, which is why ESR lives in the microwave band and NMR in the radio band.

Electron wavelength λ = c/ν sets the resonator size: centimetre cavities at X-band, millimetre resonators at W-band. At NMR frequencies the wavelength is metres, so the probe is a small coil much smaller than λ.
Interactive · equation 1.9

Population difference and polarization

The signal comes from the small excess of spins in the lower level. The horizontal axis is logarithmic: at room temperature a proton population difference of a few parts in 10⁵ is typical, while electron polarization is roughly 658 times larger at the same field.

Hyperpolarization methods such as dynamic nuclear polarization (DNP) transfer the large electron polarization to nuclei. The theoretical enhancement for ¹H is γe/γH ≈ 658; see hybrid methods.
Interactive · equations 1.2, 1.5, 4.2

Energy-level diagrams

NMR spectrometers hold the field and excite a band of frequencies. CW ESR holds the frequency and sweeps the field, so a resonance is read off at the field where the level gap equals hν. Add a hyperfine-coupled proton to see how one ESR line splits into two (ΔmS = ±1, ΔmI = 0).

Theory

Spin Hamiltonians and their energy scales

Both techniques are interpreted through an effective spin Hamiltonian. The terms map onto each other, but their sizes differ by orders of magnitude, and so does which term dominates the spectrum.

NMR Hamiltonian frequency units

  • In isotropic solution, rapid tumbling averages D and the anisotropic parts of σ and Q to zero. Only δ and J remain, giving sharp lines under 1 Hz.
  • In solids, magic-angle spinning at θm = 54.74° removes the (3cos²θ − 1) dependence.
  • Karplus relation for vicinal couplings: ³J(φ) = A cos²φ + B cos φ + C.

ESR Hamiltonian energy units

  • g and A are tensors. In frozen solutions every orientation contributes, giving powder patterns with g∥ and g⊥ features.
  • Isotropic hyperfine is the Fermi contact term: aiso = (2μ₀/3) geμB gNμN |ψ(0)|².
  • McConnell relation for π radicals: aH = Q ρC, with Q ≈ −2.3 mT.

Typical magnitudes of each interaction

NMR termsESR terms

Approximate ranges in Hz on a log scale, compiled from typical literature values. Conversions: 1 mT of hyperfine ≈ 28 MHz for g ≈ 2; 1 cm⁻¹ ≈ 30 GHz. The electron's smallest interactions are comparable to the nucleus's largest.

Interactive · first-order simulation

Spectrum simulator

Coupling to n equivalent spins of quantum number I gives 2nI + 1 lines. NMR shows absorption lines on a ppm axis drawn high-to-low; CW ESR shows the first derivative on a field axis, a side-effect of field modulation and lock-in detection.

Dynamics

Relaxation and experimental timescales

Electron spins relax roughly 10³ to 10⁶ times faster than nuclear spins. Pulsed ESR therefore needs nanosecond pulses, sub-microsecond detection and often cryogenic temperatures, while NMR pulse sequences can last seconds.

NMRESRMolecular motion

Ranges are indicative. ESR T₁ spans nanoseconds for fast-relaxing transition-metal ions at room temperature to milliseconds for organic radicals near 10 K. A nitroxide's CW lineshape is most sensitive to τc between about 10⁻¹¹ and 10⁻⁷ s, which is why spin labels report on protein and membrane dynamics.

Reference

Side by side

Filter by category. Values are typical for commercial instruments.

PropertyNMRESR / EPR
Probed spinNuclei with I ≠ 0 (¹H, ¹³C, ¹⁵N, ¹⁹F, ³¹P …)Unpaired electrons, S ≥ ½
Magnetic momentμN = 5.051 × 10⁻²⁷ J T⁻¹μB = 9.274 × 10⁻²⁴ J T⁻¹ (≈ 1836 μN)
Resonance frequencyMHz, radio frequency (¹H: 60 MHz – 1.2 GHz)GHz, microwave (1–263 GHz commercially, THz in high-field labs)
Spectral parameterChemical shift δ (ppm), J (Hz), dipolar and quadrupolar couplingsg-tensor, hyperfine tensor A (mT or MHz), zero-field splitting D, E
Thermal polarization, 300 K¹H at 9.4 T: ≈ 3 × 10⁻⁵X-band: ≈ 8 × 10⁻⁴; W-band: ≈ 7.5 × 10⁻³
RelaxationT₁ ms – s (hours in some solids), T₂ µs – sT₁ ns – ms, Tm ≈ 10 ns – 10 µs
Linewidth0.1 – 1 Hz in solution; kHz in static solids0.01 – 10 mT (≈ 0.3 – 300 MHz)
MagnetSuperconducting solenoid, fixed field, ppb homogeneity, ²H lockElectromagnet (X, Q band) or superconducting sweep magnet (W band and above)
Excitation and sweepFixed B₀, broadband RF pulse, Fourier transformCW: fixed ν, swept B₀. Pulsed: fixed B₀, spectra of limited bandwidth
Detector elementTuned RF coil (saddle or solenoid), often cryogenically cooledResonant cavity or loop-gap resonator, quality factor Q ≈ 100 – 10 000
DetectionQuadrature detection of the free-induction decay or echo100 kHz field modulation plus lock-in, giving the derivative; or echo detection
π/2 pulse length≈ 5 – 20 µs (solution), 2 – 3 µs (solids)≈ 4 – 20 ns, needing TWT or solid-state amplifiers
Sample requirementDiamagnetic preferred; paramagnets broaden and shift linesMust be paramagnetic: radicals, transition-metal and lanthanide ions, triplets, defects
Sensitivity≈ 10¹⁵ – 10¹⁷ spins (µM – mM concentrations)≈ 10¹⁰ – 10¹² spins for a narrow line (nM – µM)
Sample formSolution in deuterated solvent, 0.2 – 0.6 mL; MAS rotors for solidsLiquids in flat cells or capillaries (water absorbs microwaves); frozen solutions; powders; crystals
TemperatureMostly room temperatureRoom temperature for CW radicals; 4 – 80 K for pulsed work and fast relaxers
Labelling¹³C, ¹⁵N, ²H isotopic enrichment for biomoleculesSite-directed spin labelling (e.g. MTSL nitroxide), Gd³⁺ and trityl tags
Core observableAtom-level connectivity, conformation, dynamics of the whole moleculeElectronic structure and environment of the paramagnetic centre only
DistancesNOE: < 0.5 – 0.6 nm; PRE: up to ≈ 2.5 nmDEER/PELDOR: ≈ 1.5 – 8 nm, up to ≈ 16 nm in deuterated systems
Key multi-pulse methodsCOSY, TOCSY, NOESY, HSQC, HMBC, TROSY, CP-MAS, REDOR, relaxation dispersionHahn echo, ESEEM, HYSCORE, ENDOR, DEER/PELDOR, RIDME, saturation recovery
Typical applicationsStructure elucidation, protein structure and dynamics, metabolomics, materials, MRIRadical chemistry, catalysis, metalloproteins, spin labelling, defects in semiconductors, dosimetry, spin qubits
Where the two meet

Hybrid methods

Many modern experiments use electron and nuclear spins together. These three are the ones most PhD projects touch.

NMR signal, electron source

Dynamic nuclear polarization

Microwave irradiation near the electron resonance transfers electron polarization to nuclei (Overhauser, solid, cross and three-spin effects). MAS-DNP typically runs at ≈ 100 K with nitroxide biradicals such as AMUPol.

ESR sensitivity, NMR resolution

ENDOR and ESEEM

ENDOR detects nuclear transitions through a change in the ESR signal. Lines appear at the nuclear Larmor frequency split by the hyperfine coupling, which resolves couplings hidden under a broad ESR line.

NMR of paramagnetic systems

PRE and pseudocontact shifts

An unpaired electron enhances nuclear relaxation as r⁻⁶ and, if its susceptibility is anisotropic, shifts nuclear resonances as r⁻³. Both give long-range distance and orientation restraints.

DEER distance calculator

The dipolar oscillation period 1/ν⊥ must fit within the observable time window, which is limited by the phase-memory time Tm. That is why long distances need deuteration and low temperatures.

Interactive

Which technique fits my question?

Answer four questions for a starting recommendation. It is a heuristic to bring to a discussion with your facility manager, not a rule.

Does the sample contain unpaired electrons?
What do you need to learn?
How much sample do you have?
Is the system large, heterogeneous or insoluble (membranes, aggregates, cells)?
Self-check

Test your understanding

Work each one out before opening the answer.

1. A W-band spectrometer runs at 94.0 GHz. At what field does a free-electron-like radical (g = 2.0023) resonate?
2. A nitroxide has a ¹⁴N hyperfine coupling of 1.6 mT. How many lines appear, and with what intensities?

¹⁴N has I = 1, so 2nI + 1 = 3 lines of equal intensity (1:1:1), spaced 1.6 mT ≈ 45 MHz apart. Differences in their widths and heights encode the rotational correlation time.

3. Why is CW ESR shown as a first derivative, while NMR spectra are shown as absorption?

CW ESR modulates the field at typically 100 kHz and detects the signal with a lock-in amplifier at that frequency. When the modulation amplitude is small compared with the linewidth, the output is proportional to dχ″/dB. This suppresses low-frequency noise. NMR records a time-domain FID, and after Fourier transform and phasing the absorption mode is displayed directly.

4. Compare the ¹H polarization at 14.1 T and 298 K with the electron polarization at 0.34 T and 298 K.

Even with a field 40 times smaller, the X-band electron polarization is about 16 times larger.

5. An organic radical has a Lorentzian ΔBpp of 0.1 mT. Estimate T₂.
6. Why do paramagnetic impurities ruin a high-resolution NMR spectrum?

The fluctuating local field of an unpaired electron, about 658 times stronger than a proton's, drives very efficient nuclear relaxation. The paramagnetic relaxation enhancement scales as γe²γN²/r⁶ (Solomon–Bloembergen). Short T₂ means broad lines, and nuclei within about 1 nm can broaden beyond detection.