Nuclear magnetic resonance and electron spin resonance (also called EPR) both drive transitions between Zeeman levels of a spin in a magnetic field. The electron's magnetic moment is about 658 times larger than the proton's. That single number shifts the frequencies, the populations, the relaxation times, the hardware and the questions each method answers. This page works through those consequences with equations and live calculators.
A magnetic moment in a static field B₀ has 2S+1 or 2I+1 Zeeman levels. Radiation of frequency ν drives magnetic-dipole transitions with Δm = ±1 when hν matches the level splitting. What differs is the size and sign of the moment.
Move the field. At any B₀ the electron resonates about 658 times higher than ¹H, which is why ESR lives in the microwave band and NMR in the radio band.
The signal comes from the small excess of spins in the lower level. The horizontal axis is logarithmic: at room temperature a proton population difference of a few parts in 10⁵ is typical, while electron polarization is roughly 658 times larger at the same field.
NMR spectrometers hold the field and excite a band of frequencies. CW ESR holds the frequency and sweeps the field, so a resonance is read off at the field where the level gap equals hν. Add a hyperfine-coupled proton to see how one ESR line splits into two (ΔmS = ±1, ΔmI = 0).
Both techniques are interpreted through an effective spin Hamiltonian. The terms map onto each other, but their sizes differ by orders of magnitude, and so does which term dominates the spectrum.
Approximate ranges in Hz on a log scale, compiled from typical literature values. Conversions: 1 mT of hyperfine ≈ 28 MHz for g ≈ 2; 1 cm⁻¹ ≈ 30 GHz. The electron's smallest interactions are comparable to the nucleus's largest.
Coupling to n equivalent spins of quantum number I gives 2nI + 1 lines. NMR shows absorption lines on a ppm axis drawn high-to-low; CW ESR shows the first derivative on a field axis, a side-effect of field modulation and lock-in detection.
Electron spins relax roughly 10³ to 10⁶ times faster than nuclear spins. Pulsed ESR therefore needs nanosecond pulses, sub-microsecond detection and often cryogenic temperatures, while NMR pulse sequences can last seconds.
Ranges are indicative. ESR T₁ spans nanoseconds for fast-relaxing transition-metal ions at room temperature to milliseconds for organic radicals near 10 K. A nitroxide's CW lineshape is most sensitive to τc between about 10⁻¹¹ and 10⁻⁷ s, which is why spin labels report on protein and membrane dynamics.
Filter by category. Values are typical for commercial instruments.
| Property | NMR | ESR / EPR |
|---|---|---|
| Probed spin | Nuclei with I ≠ 0 (¹H, ¹³C, ¹⁵N, ¹⁹F, ³¹P …) | Unpaired electrons, S ≥ ½ |
| Magnetic moment | μN = 5.051 × 10⁻²⁷ J T⁻¹ | μB = 9.274 × 10⁻²⁴ J T⁻¹ (≈ 1836 μN) |
| Resonance frequency | MHz, radio frequency (¹H: 60 MHz – 1.2 GHz) | GHz, microwave (1–263 GHz commercially, THz in high-field labs) |
| Spectral parameter | Chemical shift δ (ppm), J (Hz), dipolar and quadrupolar couplings | g-tensor, hyperfine tensor A (mT or MHz), zero-field splitting D, E |
| Thermal polarization, 300 K | ¹H at 9.4 T: ≈ 3 × 10⁻⁵ | X-band: ≈ 8 × 10⁻⁴; W-band: ≈ 7.5 × 10⁻³ |
| Relaxation | T₁ ms – s (hours in some solids), T₂ µs – s | T₁ ns – ms, Tm ≈ 10 ns – 10 µs |
| Linewidth | 0.1 – 1 Hz in solution; kHz in static solids | 0.01 – 10 mT (≈ 0.3 – 300 MHz) |
| Magnet | Superconducting solenoid, fixed field, ppb homogeneity, ²H lock | Electromagnet (X, Q band) or superconducting sweep magnet (W band and above) |
| Excitation and sweep | Fixed B₀, broadband RF pulse, Fourier transform | CW: fixed ν, swept B₀. Pulsed: fixed B₀, spectra of limited bandwidth |
| Detector element | Tuned RF coil (saddle or solenoid), often cryogenically cooled | Resonant cavity or loop-gap resonator, quality factor Q ≈ 100 – 10 000 |
| Detection | Quadrature detection of the free-induction decay or echo | 100 kHz field modulation plus lock-in, giving the derivative; or echo detection |
| π/2 pulse length | ≈ 5 – 20 µs (solution), 2 – 3 µs (solids) | ≈ 4 – 20 ns, needing TWT or solid-state amplifiers |
| Sample requirement | Diamagnetic preferred; paramagnets broaden and shift lines | Must be paramagnetic: radicals, transition-metal and lanthanide ions, triplets, defects |
| Sensitivity | ≈ 10¹⁵ – 10¹⁷ spins (µM – mM concentrations) | ≈ 10¹⁰ – 10¹² spins for a narrow line (nM – µM) |
| Sample form | Solution in deuterated solvent, 0.2 – 0.6 mL; MAS rotors for solids | Liquids in flat cells or capillaries (water absorbs microwaves); frozen solutions; powders; crystals |
| Temperature | Mostly room temperature | Room temperature for CW radicals; 4 – 80 K for pulsed work and fast relaxers |
| Labelling | ¹³C, ¹⁵N, ²H isotopic enrichment for biomolecules | Site-directed spin labelling (e.g. MTSL nitroxide), Gd³⁺ and trityl tags |
| Core observable | Atom-level connectivity, conformation, dynamics of the whole molecule | Electronic structure and environment of the paramagnetic centre only |
| Distances | NOE: < 0.5 – 0.6 nm; PRE: up to ≈ 2.5 nm | DEER/PELDOR: ≈ 1.5 – 8 nm, up to ≈ 16 nm in deuterated systems |
| Key multi-pulse methods | COSY, TOCSY, NOESY, HSQC, HMBC, TROSY, CP-MAS, REDOR, relaxation dispersion | Hahn echo, ESEEM, HYSCORE, ENDOR, DEER/PELDOR, RIDME, saturation recovery |
| Typical applications | Structure elucidation, protein structure and dynamics, metabolomics, materials, MRI | Radical chemistry, catalysis, metalloproteins, spin labelling, defects in semiconductors, dosimetry, spin qubits |
Many modern experiments use electron and nuclear spins together. These three are the ones most PhD projects touch.
Microwave irradiation near the electron resonance transfers electron polarization to nuclei (Overhauser, solid, cross and three-spin effects). MAS-DNP typically runs at ≈ 100 K with nitroxide biradicals such as AMUPol.
ENDOR detects nuclear transitions through a change in the ESR signal. Lines appear at the nuclear Larmor frequency split by the hyperfine coupling, which resolves couplings hidden under a broad ESR line.
An unpaired electron enhances nuclear relaxation as r⁻⁶ and, if its susceptibility is anisotropic, shifts nuclear resonances as r⁻³. Both give long-range distance and orientation restraints.
The dipolar oscillation period 1/ν⊥ must fit within the observable time window, which is limited by the phase-memory time Tm. That is why long distances need deuteration and low temperatures.
Answer four questions for a starting recommendation. It is a heuristic to bring to a discussion with your facility manager, not a rule.
Work each one out before opening the answer.
¹⁴N has I = 1, so 2nI + 1 = 3 lines of equal intensity (1:1:1), spaced 1.6 mT ≈ 45 MHz apart. Differences in their widths and heights encode the rotational correlation time.
CW ESR modulates the field at typically 100 kHz and detects the signal with a lock-in amplifier at that frequency. When the modulation amplitude is small compared with the linewidth, the output is proportional to dχ″/dB. This suppresses low-frequency noise. NMR records a time-domain FID, and after Fourier transform and phasing the absorption mode is displayed directly.
Even with a field 40 times smaller, the X-band electron polarization is about 16 times larger.
The fluctuating local field of an unpaired electron, about 658 times stronger than a proton's, drives very efficient nuclear relaxation. The paramagnetic relaxation enhancement scales as γe²γN²/r⁶ (Solomon–Bloembergen). Short T₂ means broad lines, and nuclei within about 1 nm can broaden beyond detection.